Durability of Saflex® Structural mechanical properties

Date: 9 April 2021
Copyright:
  • Eastman Architectural Advanced Interlayers
  • https://www.saflex.com/saflex-guide/articles/durability-saflex%C2%AE-structural-mechanical-properties

Date: 9 April 2021

The determination of interlayer modulus data is complex.

Interlayer modulus—a measure of the stiffness of the interlayer—influences the stress that laminated glass experiences under load. The determination of interlayer modulus data is complex. Over the last five years, several developments have influenced the determination of interlayer modulus properties and its use in laminated glass design.

Significant research has been done by academia and the industry to optimize, compare, and expand measurement methods and data processing methodology, complemented with sensitivity analysis and, in some cases, inclusion of these data in standards. The combined effort has led to a better understanding of best practices for methods and data treatment and validation.

So far, no data are available to demonstrate that the mechanical properties of the interlayer as used in laminated safety glass remain stable over time. In a few cases, the behavior of the interlayer under various exposure or weathering conditions was studied on the interlayer itself, but this can’t be considered representative for the laminated glass product.

 

Interlayers condition test

To study the effect of UV radiation and temperature, Eastman initiated a study in which the conditions of the international laminated glass standard EN ISO 12543-4 radiation test were applied to laminates comprising Saflex Structural interlayer. Characterization of the mechanical properties before and after the test, at various temperatures, was performed. The testing was done at the Institute for Building Construction and Physics at the University of the German Armed Forces.

Glass specimens (n = 3) consisting of 6-mm glass, 0.76-mm Saflex Structural, and 6-mm glass (also known as 66.2DG) in a format of 3600 x 1100 mm were prepared on a commercial lamination line. After production, the panels were subjected to a four-point bending test (EN 1288-3) in creep mode using a 250 N load at temperatures of 20°, 30°, and 50°C. Deflections were monitored for 72, 48, and 24 hours respectively. The setup is demonstrated in Figure 1.

Figure 1: Glass laminate samples in temperature chamber for four-point bending characterization
Figure 1: Glass laminate samples in temperature chamber for four-point bending characterization

 

Setup of the UV radiation test

Subsequently, the panels were exposed to the radiation test of EN ISO 12543-4 as shown in Figure 2. The test conditions comprise a duration of 2000 hours at a temperature of 45°C in combination with intense UV radiation.

Figure 2. Setup of the UV radiation test (glass edges have been marked in blue for clarity)
Figure 2. Setup of the UV radiation test (glass edges have been marked in blue for clarity)

After exposure to radiation, the characterization using the four-point bending test was repeated. Test results of the three temperatures are shown in Figure 3. Test results obtained initially are marked I (solid lines), and test results obtained after exposure are marked A (for aged, dotted lines). The major observation is that the solid and dotted lines virtually overlap, indicating that the mechanical properties of Saflex Structural are stable under the exposure conditions of EN ISO 12543-4.

It is also clear that, at 20°C, hardly any relaxation of the glass laminate takes place over a 72-hour period, indicating the rigidity of the interlayer at this temperature. Deflections measured are close to the calculated deflection of a 12-mm monolithic glass panel. At 50°C, relaxation is relatively rapid and significant deflection is measured at the start of the experiment. However, some degree of coupling is still achieved as the laminate continues to relax for the duration of this experiment. As expected, at 30°C, an intermediate behavior is observed and gradual relaxation of the interlayer occurs over time.

The design engineer can be confident that the properties reported for Saflex Structural interlayers are stable with respect to the exposure conditions of the international laminated glass standard. Saflex Structural interlayer can fulfill its support contribution to the glazing for the design life of the building.

Figure 3. Deflections of Saflex Structural interlayer over time as a function of temperature in four-point bending creep (x-axis has logarithmic scale)
Figure 3. Deflections of Saflex Structural interlayer over time as a function of temperature in four-point bending creep (x-axis has logarithmic scale)
600450 Durability of Saflex® Structural mechanical properties glassonweb.com

Others also read

This paper focuses on a numerical investigation of the in-plane behavior of an innovative steel-reinforced glass frame prototype, designed to incorporate (partially) UV-curable beam-column connections.
Visual defects, in particular haze, in glass and façade technologies can significantly impact the aesthetic quality and human experience of daylight and views in buildings.
This paper introduces the concept of a numerical sensor as a key element for creating a hybrid digital twin focused on the monitoring of load-bearing glass façades.
This paper presents investigations on a novel approach for post-tensioning laminated glass beams with adhesively bonded iron-based shape memory alloy tendons along both longitudinal glass beam edges.
In this paper, the anticlastic cold bending test was conducted to explore the influence of various factors, including aspect ratio, scale and composition of the plates.
This paper investigates the post-fracture spring-back effect and the post fracture behaviour in warm bent glass, aiming to assess its safe use in structural glass applications.

FROM INDUSTRY

52 Corniche El-Nil, AL-SHARIFAIN Tower 10th Floor,
Maadi,
Cairo Governorate
11728
Egypt

Room 201 - 401 , Building B1, Hengli Industrial Park, no. 168, Weikeng Road, Tongde Community, Baolong Street
Longgang Qu
Shenzhen Shi
Guangdong Sheng, 518115
China

İçmeler Mah. D-100 Karayolu Cad. No:44A,
34947 Tuzla,/İstanbul
Turkey

Pol. Ind. Penapurreira Parcela C4-B,
15320 As Pontes de García Rodríguez A Coruña
Spain

2200 W. Salzburg Rd.
Auburn , MI 48611
United States

Ottergemsesteenweg 707-Zuid
9000 Ghent
Belgium

Add new comment