Wrightstyle, Queen Boudicca and King's Cross tragedy

Date: 6 April 2012

A leading UK steel glazing company has supplied fire-rated systems to the iconic King’s Cross redevelopment in London.

Wrightstyle’s technical director Lee Coates reports.



It was completed in 1852 on the site of a former smallpox hospital, is reputedly haunted by the ghost of Queen Boudicca and is the railway station from which, as every Harry Potter fan knows, you catch the train for Hogwarts. Work on the over £500 million redevelopment of King’s Cross railway station in London began in 2007, part of a much wider £2.2 billion regeneration project for the area that will see 3.4 million sq ft of office space, 2,000 homes, 500,000 sq ft of retail space, 300 hotel bedrooms, and 650 student units.  Already completed is the University of the Arts London, which opened towards the end of last year.



Centrepiece of the redevelopment of the station which handles 47 million station users annually is the newly-opened western concourse, with new passenger facilities, shops and restaurants as well as improved access to the Underground, Thameslink and the adjacent St. Pancras station, terminus for the cross-Channel Eurostar. 



Final works on King’s Cross are due to be completed by the end of next year which will see the existing canopy removed, a new public square opened and the original Victorian structure revealed, reinventing the station at the heart of a major commercial, residential and transport hub.



Security is of paramount importance, not least because of the 2005 bombing outrage, which killed 52 people, with the four bombers traveling into King’s Cross before their murderous attacks.  Although it remains the worst terrorist attack in London, it wasn’t the first at the station.  In 1973, a Provisional IRA bomb also detonated in King’s Cross’s booking hall, injuring six people, several seriously.



Appalling as those incidents were, it was a major fire at the station in 1987 which has had arguably the greater influence on public safety.  Started most probably by a discarded match, despite smoking having been banned in the Underground two years earlier, the source of the fire was an escalator shaft dating back to before World War II.  It was partially built from flammable wood and the running track of the escalator had not been cleaned since the 1940s and was covered in grease and filled with rubbish.



The fire claimed the lives of 31 people, including a fire fighter and a homeless man who wasn’t identified until 2004.  Dozens more were injured.



However, the importance of the tragedy in the evolving story of fire safety is that its severity was initially inexplicable. There was a lack of visible flames, and the firemen first on the scene - who had attended other similar fires - believed that it posed little threat.  Indeed, fire-fighters later described it as being about the size and intensity of a campfire.



Amid the complacency, the situation rapidly became worse, with the fire appearing to flash over and fill the ticket hall with flames and smoke.  Far from now being a campfire, fire-fighters trying to re-enter the ticket hall described conditions as similar to climbing into a volcano.



It was later shown that a combination of wind movements caused by underground trains arriving and leaving created a 12mph wind in a “piston effect”, pushing air from the tunnels upwards and adding to the speed of the fire spreading.  However, it took groundbreaking computer modeling and fire simulation, then in its infancy, to promote a new theory of fire development within inclined shafts.



That theory is called the trench effect, and involved hot gases in the buoyant plume to lie along the escalator surface, creating a rapid airflow that caused the gases to move up the escalator, increasing in proportion to the size of the fire, and eventually creating an effect much like a flamethrower, sending flames shooting upwards into the ticket hall.



The computer modeling of the “fluid flow” of the fire helped to substantially advance the science of fire dynamics, using computational simulation to look at how fires behave, with an emphasis on smoke and heat movement from their source.



The subsequent Fennell Investigation into the fire prompted the replacement of all wooden escalators on the Underground, the installation of automatic sprinklers and heat detectors in escalators, mandatory fire safety training for all station staff twice a year, and improvements in emergency services liaison.



The King’s Cross fire, and the impact of computer modeling, has helped inform fire training since and also influenced how companies such as Wrightstyle, which has been significantly involved in complex transportation projects, design the steel glazing systems that mitigate against threats caused by fire.



In supplying glazed components to the frontage of the new King’s Cross, we have brought a wealth of experience and expertise from other UK transport infrastructure projects, as well as overseas contracts in Hong Kong and, more recently, for the Dubai metro.  Our advice to specifiers, based on extensive fire and bomb testing, is simple: always specify the glass and steel components as one integrated and tested assembly.



At King’s Cross, working with Hatfield-based Design Rationale, the specialist architectural metalwork and glazing contractor, our large-span systems provide a safe evacuation route from the main administrative areas and, underlining the historic importance of the Grade 1 listed station, were also designed in consultation with English Heritage. 



Network Rail promises that the new King’s Cross will be world-class.  However, in another important aspect – fire safety – the new station has also had to learn painful lessons from its past, to build a facility offering the safest possible transit for its millions of customers every year.



Boudicca, queen of the Iceni who led a revolt against the Romans, is reputedly buried under platforms 8, 9 or 10.  It’s possible that the Battle of Watling Street, at which she was finally defeated, took place where the station now stands.  Her ghost is said to inhabit some of the underground passages.  It’s also a place of pilgrimage for budding wizards, with Network Rail designating a Platform 9¾ with a luggage trolley half buried into the wall, although rail services only go as far as Scotland. 

 

www.wrightstyle.co.uk 

 

Main contractor for the project is VINCI Construction UK, the national construction and facilities company, part of VINCI, a world leader in concessions and construction.

 

Ends

 

For further information:

 

Jane Embury, Wrightstyle

+44 (0) 1380 722 239

jane.embury@wrightstyle.co.uk 

 

Media enquiries to Charlie Laidlaw, David Gray PR

Charlie.laidlaw@yahoo.co.uk

+44 (0) 1620 844736

(m) +44 (0) 7890 396518

600450 Wrightstyle, Queen Boudicca and King's Cross tragedy glassonweb.com

Others also read

For the first time in 20 months, architecture billings have reached a point of stability, according to the October AIA/Deltek Architecture Billings Index (ABI), which posted a score of 50.3.
With the steady progress of the NorthGlass High-End Equipment Industrial Park project, the landmark R&D Center Building’s "Super Glass" curtain wall has been successfully installed.
Mississippi’s first dedicated children’s hospital, the Sanderson Tower, combines advanced care and modern design with Vitro’s Solarban® 90 glass for a bright, welcoming space.
Building on the success of Glasstec 2024, Pujol and Evalam are set to continue their tour at the highly anticipated Eurasia Glass Fair 2024, the premier trade fair for the glass industry in the Eurasia region.
Thermal Bridging Considerations at Interface Conditions, Key Strategies for Bird Friendly Glazing School Security coming soon
Dubai Municipality, Abu Dhabi Projects & Infrastructure Centre, Department of Municipalities & Transport, Expo City to headline summits at Big 5 Global and LiveableCitiesX

Add new comment

From industry

Via Del Lavoro Snc
64023 Mosciano Sant’Angelo TE
Italy

NEWS RELATED PRODUCTS

Hornos Industriales Pujol
Hornos Industriales Pujol
Hornos Industriales Pujol
Hornos Industriales Pujol
Hornos Industriales Pujol