Glass elevations are a determinant of contemporary architectural designs - both in modern office buildings and in revitalized facilities.

Façade glazing is, however, quite a challenge, because in addition to all the aesthetic advantages, they must be characterized by parameters that allow obtaining the most advantageous energy balance of the building. Architects’ expectations regarding the properties of facade glass are still growing.

If the regulations require that the glass façade envisaged in the project should have fire resistance properties, these stricter spectrophotometric, thermal and acoustic requirements must also be met by fire protection glass.

To begin with, there is a question of the spectrophotometric parameters, i.e. the transmittance of light - this is why we use glass. POLFLAM glass has a very high Lt coefficient. The trick is to avoid excessive overheating of the rooms in the summer while maintaining high transparency.

Also in this case POLFLAM is a technological leader: the solar factor SF, that is the total solar energy transfer coefficient (g), is very low – it oscillates around 20%, depending on the applied coating.

Another important point is the question of the amount of heat loss, or glass insulation. The ability to combine our glass with coating glass of different kinds with very good thermal properties allows achieving excellent parameters. The Ug coefficient for two-chamber glass units combined with POLFLAM glass can amount to 0.5 W / m2 K.

Bank Zachodni WBK – head office in Wroclaw. POLFLAM glass was used in the facade of the building with the required fire resistance
Bank Zachodni WBK – head office in Wroclaw. POLFLAM glass was used in the facade of the building with the required fire resistance

And one more thing. The glass has better insulation parameters than the frame construction, and both of these elements determine the thermal properties of the whole partition.

Thus, the greater the proportion of glass in the façade and the fewer the joinery therein, the more advantageous the Uw coefficient is, which determines the scale of heat losses - the key for the energy balance of the facility. Therefore, in the case of facades, largest possible sheets of glass are so desirable. The POLFLAM company has made the large-format fire-resistant glass its hallmark.

Next parameter – acoustic insulation, especially important in urban development. The POLFLAM glass technology provides excellent soundproofing parameters, even those recommended in places with particularly high noise levels. And thanks to the application of appropriate extra glass panes, you can achieve an Rw coefficient of up to 52 dB.

When in the façade the fire protection glass is combined with glass without fire resistance, the question of their color coherence comes to the fore. In the case of POLFLAM glass, it is not difficult.

Float glass used in its production is characterized by high color neutrality, and the fireproof gel creates a perfectly transparent layer. The possibility of selective glass in a wide range of shades to be added to fire-resistant panels allows you to easily adjust the fireproof part to the remaining surface of the facade.

The certified tools that POLFLAM has at its disposal allow for the estimation of spectrometric, thermal and acoustic parameters of glass packets and the matching of appropriate combinations for specific projects. With such a product and professional tools it is easy to meet even the highest expectations of investors and architects, and at the same time meet the requirements marked by technical conditions.

POLFLAM glass in the facade of Oxygen Park: a modern office complex in the business area of Warsaw
POLFLAM glass in the facade of Oxygen Park: a modern office complex in the business area of Warsaw

 

600450 POLFLAM glass in facades – top-end requirements glassonweb.com

Others also read

Apply by 28 Feb. to drive façade innovation further!
Guardian Glass is marking the 30th anniversary of the SunGuard™ architectural low-E coated glass product line in 2025.
A recent evaluation by ift Rosenheim has validated the performance of the Sparklike Handheld 3.0™ for measuring gas concentration in insulating glass units (IGUs).
Sparklike is proud to celebrate a major milestone: the delivery of their 2000th Sparklike Handheld device to Insul-Lite Manufacturing.
In a few days, the leading trade fair BAU will open its doors and the Glas Trösch Group will once again be represented in Munich.
When it comes to energy-efficient windows, the role of gas filling in insulating glass units (IGUs) cannot be overstated.

Add new comment

From industry

İçmeler Mah. D-100 Karayolu Cad. No:44A,
34947 Tuzla,/İstanbul
Turkey

2200 W. Salzburg Rd.
Auburn , MI 48611
United States

52 Corniche El-Nil, AL-SHARIFAIN Tower 10th Floor,
Maadi,
Cairo Governorate
11728
Egypt

NEWS RELATED PRODUCTS

A+W Software GmbH
Guardian Glass Europe
Glas Trösch Holding AG
Glaston Corporation